boyard

Холодильно-Морозильні моноблоки все-в-одному Інверторні / старт-стоп

Inverter refrigeration and freezing Condensing units

The main advantage of BOYARD Units is their size, which makes them the most compact in the world and their height reaches no more than 20 cm, which makes it possible to install them in places with limited space.

INVERTER Condensing Units – Smooth adjustment of compressor power, which guarantees durability, energy efficiency by more than 25%, low noise level, fast and accurate temperature control ±0.5°C. And there is also the possibility of connecting several units of equipment and equipment to it;

Cooling temperature from -30°C to +15°C will be provided by the exceptional versatility of the Units, which is absent in other similar cooling systems due to technical features.

BOYARD rotary refrigeration compressors are installed in all models of Units, which have significant technical and economic advantages over more traditional piston compressors.

Cooling capacity: 0.75 – 3 hp
Refrigerant: R404A/R448A/R449A/R454C, etc. as per your request
Voltage: 1 phase / 220V / 50~60Hz;

UNIT PROTECTION SYSTEM

  • System protection against low and high pressure: if the high or low pressure values ​​in the system are exceeded, the Unit control board will warn about this with an audible signal and an error code output, and if the pressure limit value is exceeded, the system will automatically shut down until the pressure stabilizes and restart the system.
  • System protection against excessive discharge and condensation temperatures: if the discharge and condensation temperatures are exceeded, the Unit control board will warn about this with an audible signal and an error code output, and if the temperature limit value is exceeded, the system will automatically shut down until the temperature stabilizes and restart the system.
  • System protection against liquid freon shock (water hammer): by monitoring the temperature difference in the system, the control board will stop the system to stabilize the temperatures.
  • Compressor overheating protection: using the discharge temperature control, when the value is reached, the liquid cooling system of the compressor will be turned on, which will ensure uninterrupted operation of the compressor under high loads on the system.
  • Compressor protection against low ambient temperatures: if the Monoblock is operated at low ambient temperatures, there is a risk of compressor oil thickening and proper lubrication of its parts. The compressor is equipped with an electric heater that will automatically heat the compressor oil when the ambient temperature values ​​are reached.
  • Unit electrical power protection:
    High voltage protection
    System blocking after three power errors.

Technical specifications

Horizontal Frequency Conversion Unit Technical Data
ModelHQSD-150KBI40(a)HQSD-210KBI41(a)HQSD-285KBI40(a)HQSD-360KBI40(a)HQSD-460KBI40(a)HQSD-540KBI40(a)
① Nominal Input (W)120012001550195025502890
Power Supply220V 50/60 Hz
RefrigerantR404A or Equivalent
Refrigerant Max. (Kg)1,51,82,53,53,54,5
② Max Running Current (A)6610,513,516,520
Evap. Temp (°C)-40 ~ -5°C
Ambient Temp (°C)10 ~ 43°C
Compressor (Model)JHSD150Z312JHSD150Z312KHSD203Z312KHSD300Z312KHSD300Z312THSD456Z312
CondenserStyleCopper tube fin condenser or microchannel condenser
Fam MotorDiameter (mm)φ230*2 (EC)φ230*2 (EC)φ230*3 (EC)φ230*3 (EC)φ230*4 (EC)φ254*4 (EC)
Air Flow (m3/hr)730*2730*2730*3730*3730*4840*4
Basic configurationPressure Controller (Mpa)Diaphragm type: high pressure switch, Low Pressure Sensor
Reservoir0,6L0,8L1,1L
Oil separatorBLR/A-W 55833
Accumulator650CC1200CC1L
Dryer filter083S
Liquid Valve1/4
Variable frequency control functionCompressor frequency control, electronic expansion valve control, condensing fan control, defrosting control, high and low pressure protection, spray control, exhaust temperature protection, current protection and fault code output.
Pipe (mm)Gas Inlet Diam ODφ12.7(1/2″)φ15.88(5/8″)
Liquid Outlet ODφ9. 53(3/8” )
Out Dimension (mm)Length (mm)680790940114513501350
Width (mm)600600600600600600
Height (mm)251285
Weight (Kg)29,533,547536266
Noise value (dB)586061596364
Capacity (W)Evap Temp (°C)Ambient Temp:32°C           Sub-cooling 0°C
-4046059084099013201420
-355707201040126015701700
-307209101250160020002150
-2590011501500195024002600
-20111014101890245029603240
-15134017002240305032003700
-10158020002650365043004720
-5182023202950423051505600
Wiring CapacityLeak ProtectorRated Current (A)151520202020
Leak Current (mA)303030303030
Diameter (mm2)L≤10m2,02,04,04,04,04,0
10<L≤20m2,52,56,06,06,06,0
20<L≤30m2,52,56,06,06,06,0
①Refrigerating capacity test condition; ②The biggest running current test condition
TEST CONDITION (GB/T 21363-2008) :
 TEST CATIONAMBIENT TEMP.Sub-coolingRETURN GAS TEMP.EVAP. TEMP.TESTING POWER SUPPLY
STANDARD TEST CONDITIONS32°C0°C18°C`-7°C220V—50HZ
OVERLOAD RUNNING43°C0°C18°C0°C198V—50HZ

①When the unit is used in freezing condition, it is recommended to add refrigeration solenoid valve
and use negative pressure shutdown scheme;When used in refrigeration conditions, it is recommended
to add refrigeration solenoid valve;
②Refrigerating capacity test condition;
③When the unit filling refrigerant exceeds the maximum filling amount, the quality of filling chilled oil
should be confirmed with our company.
④The biggest running current test condition;
⑤When the ambient temperature is lower than 10℃, the condensation temperature control needs to be
added;

Dimensions

Download